venueoreo.blogg.se

Amp steps motor
Amp steps motor





amp steps motor
  1. Amp steps motor how to#
  2. Amp steps motor drivers#
  3. Amp steps motor full#

The only question I now have is reference the control module.Īfter looking online I've found two different part numbers for the control module. Total steps for each resolution will be 200. Specifications Its rated voltage is 12V Phase current is 2.2A The Holding torque is equal to 40N.cm One step angle will be of 1.8 Deg. Speed 120 x frequency (Hz) / poles of the motor Example 120 x 60 hertz / 4 poles 1,800 rpm. So basically what I thought was probably a motor, is looking like the control module. Internally to control the stepper motor we will have to use the green and black pair. Two pole AC motors operating at 60 Hz will always run at approximately 3600 rpm, and four pole AC motors will have speeds around 1800 rpm. Next I went and hit the control module and now it's working again, with no issue. Wait it wasn't that easy.After several tests, the board quit working and the clicking was back. Presto no more clicking the running board worked great!!! I also cleaned the hinges and sprayed them down with a Liquid Wrench, white lithium grease. I ended up cleaning the components and put the housing back on. Once I had the housing off, I looked at the rotor the brushes and everything looked pretty good and the motor turned freely.

amp steps motor

So if your step is stuck in the up position and you need to replace the motor, just pull the rear motor housing and turn the step down for clearance. This actually solved the issue of not being able to get to the motor mounting bolts as the step is stuck in the "up" position and bolts were blocked by the step itself. Once you start turning the rotor the step will begin to move up or down, depending on which way you turn it. Once the housing is off, you can turn the rotor. There are only two T-15 Torx screws that you have to remove and the rear housing comes right off. It's a bit of a quirky procedure that I had to experiment with, but it does work.Got to looking at the step today and noticed you can actually remove the rear housing of the motor.

Amp steps motor drivers#

I heard the passenger running board motors activate, then opened the drivers side door and walked around the truck, opened a passenger door and everything was OK and has been since. I sat in the drivers seat with all of the doors closed, parking brake set, key on in the RUN position, then hit the running board button 6 times. Quickly, you'll find that you'll have to be IN the truck with the doors closed in order to set the parking brake, turn the ignition to the RUN position AND push the running board on/of button. The rotor is magnetized by altering the north pole and south pole situated in a straight line parallel to the iron shaft of the rotor. It won't affect the key programming, but it worked. The typical step angles of a permanent magnet stepper motor is 7.5 degree to 15 degree.

Amp steps motor full#

I tried a bunch of times too, got frustrated just to realize that I was Initially doing it wrong.Īnother thing I did in desperation was disconnect the positive AND negative battery terminal cables and without them being connected to the battery, connect the cables to one-another for 15 minutes to do a full capacitive electrical drain/discharge on the body modules, then reconnect the battery as normal and retry the procedure TO THE LETTER. It should work as written for your 2011 as written, but again, follow the procedure to the letter. A power retract operation of the running boards will occur with the closing of both doors on that side of the vehicle.Ĭlick to expand.One thing to add is to perform the procedure as written, to the letter, but ALSO in a SILENT environment.

amp steps motor

The articulating running boards will now operate when opening either the front or rear doors on that side of the vehicle. Open right front or right rear door and the running board on the right should articulate out.Ĭlose the right front or right rear door and the running board should articulate in. Open the left front or left rear door and the running board on the left side should articulate out.Ĭlose the left front or left rear door and the running board should articulate in. Turn the ignition switch to the RUN position, with the engine off, and toggle the disable switch three times within 20 seconds to activate the power running boards. To activate and unlock the articulating running boards for normal operation, perform the following procedures:įind the running board disable switch located on the center console below the HVAC climate control system.

Amp steps motor how to#

Power running boards are locked from the factory to the dealership, this is how to unlock them as part of dealer prep. However, if you have your running boards stuck in the up or down position after a dead battery or other issues, here is how to reset them WITHOUT the need for a dealer service or scan tool: Some power running boards are stuck (in cold weather) due to lack of lubrication.







Amp steps motor